SALE PROHIBITED TO PERSONS UNDER 18 - FREE SHIPPING FROM €40 (Mainland Spain only - Max. 25 Kg)
The Milwaukee MA911B/2 PH Electrode is a replacement probe for measuring pH in aqueous solutions. It features a double junction, gel electrolyte, BNC connector, and 2-meter cable, ideal for monitoring irrigation water and nutrient solutions.

The Milwaukee MA911B/2 pH electrode is developed to perform acidity and alkalinity measurements using a compatible pH meter. Made with a resin body, it incorporates a double junction Ag/AgCl reference and a glass sensor bulb with a spherical tip.
The combination of these components allows for stable readings when the electrode is properly hydrated, clean, and calibrated.
The two-meter cable provides freedom to place the measuring equipment at a certain distance from the tank, while the BNC connection makes it easy to mount and replace worn electrodes.
It is a particularly interesting option for hydroponics, fertigation, aquariums, and nutrient solution control installations where it is important to regularly know the pH of the water.
The Milwaukee MA911B/2 PH Electrode is an electrochemical sensor designed to determine the pH level of liquids using a compatible measuring instrument. It belongs to the Milwaukee electrode range and stands out for incorporating gel electrolyte and double junction reference system.
The operating principle is based on the difference in electrical potential generated between the glass bulb sensitive to hydrogen ions and the internal reference system. The connected meter interprets this signal and displays the corresponding pH value.
The double junction reference provides additional separation between the internal system of the electrode and the sample being analyzed. This configuration helps reduce certain problems related to contamination of the reference system, especially when working with solutions containing salts and fertilizers.
The gel electrolyte eliminates the need for periodic refills, simplifying maintenance compared to certain refillable electrodes. However, the sensor requires cleaning, hydration, and regular calibrations to maintain proper operation.
The pH electrode with BNC connector has a measurement range of 0 to 14 pH and comes with a cable of approximately 2 meters. The final accuracy will depend on the meter used, calibration, sensor condition, and measurement conditions.
The Milwaukee MA911B/2 pH probe is used to determine the acidity or alkalinity of liquid solutions, providing important information for water control used in horticulture, agriculture, and various technical applications.
In indoor cultivation, keeping the pH within the appropriate values for each species and cultivation system helps promote nutrient availability. Significant changes in acidity can alter the solubility of certain mineral elements and affect plant nutrition.
This hydroponic pH electrode allows checks in fertigation tanks, prepared nutrient solutions, irrigation water, and liquid samples taken from drainage.
It can also be used to analyze aqueous extracts prepared from substrate samples. To obtain representative soil results, it is necessary to follow an appropriate extraction procedure. It is not specifically designed to directly insert the bulb into compact soils.
Main advantages include:
The Milwaukee pH measuring probe is especially useful when a previous electrode begins to show unstable readings, high response times, or difficulties in completing calibration correctly.
To use the Milwaukee MA911B/2 PH Electrode, you must first connect it to a compatible pH meter using the BNC connector and check that the sensor bulb is properly hydrated.
Before starting measurements, it is advisable to check the instrument's calibration using reference buffer solutions. For horticultural applications, pH 7.01 and pH 4.01 standards are usually used, always following the instructions of the connected equipment.
Once the meter is calibrated, insert the sensitive end of the electrode into the solution you wish to analyze. The bulb and the reference junction must come into contact with the liquid, avoiding knocks against the walls or bottom of the container.
Wait until the reading stabilizes and check the value displayed on the instrument screen. If you are monitoring a nutrient solution, perform the measurement after properly mixing the water with the fertilizers and allowing the preparation to reach homogeneous conditions.
After each reading, gently rinse the tip with distilled or deionized water to remove possible residues. This quick rinse should not be confused with storage, as pH electrodes should not be stored immersed in distilled water.
To keep the sensor in proper condition, use a specific storage solution for pH electrodes, such as Milwaukee MA9015.
If salt deposits or fertilizer residues appear, use an appropriate cleaning solution. Avoid rubbing the bulb with abrasive materials or applying pressure to the glass, as it could become damaged.
If you need to buy Milwaukee MA911B/2 electrode, at Hydroponics Blanes you will find a replacement designed to restore the measuring capacity of compatible pH equipment without having to replace the entire instrument.
The Milwaukee pH electrode replacement is especially interesting for continuous monitoring systems and equipment that regularly work with water tanks and nutrient solutions.
The manufacturer identifies this model as a compatible electrode for Milwaukee MC110 and MC120 monitors. It is also associated with other Milwaukee control equipment, although it is advisable to check the exact reference and connection type before purchasing.
Technical characteristics Milwaukee MA911B/2 PH Electrode: