- New


SALE PROHIBITED TO PERSONS UNDER 18 - FREE SHIPPING FROM €40 (Mainland Spain only - Max. 25 Kg)
pH 4.01 Calibration Solution 100 ml. AquaMaster is a standard solution for adjusting pH meters and improving irrigation control in cannabis cultivation.

The pH 4.01 Calibration Solution 100 ml. AquaMaster is a calibration solution designed to check and adjust digital pH meters when a precise acidic reference is needed.
In cannabis cultivation, correctly measuring the pH of irrigation water and nutrient solution is essential for plants to absorb nutrients in a balanced way. A misadjusted meter can show incorrect values and lead to wrong decisions when adding pH regulators, fertilizers, or additives.
This pH 4.01 solution allows for more complete calibrations, especially when combined with a pH 7.00 solution for two-point calibration.
The 100 ml format is convenient for growers working in tents, indoor rooms, coco systems, soil, hydroponics, RDWC, NFT, or aeroponics.
In addition, it features traceability according to NIST standards, an important detail for those seeking reliable references in measurement tasks.
At 25 °C, the indicated value is pH 4.01, although it may change slightly depending on temperature: at 20 °C it remains at 4.00, at 35 °C it goes to 4.02, at 45 °C it reaches 4.05, and at 60 °C it reaches 4.10. Therefore, it is advisable to consider the temperature of the liquid during calibration.
To store it properly, the container must be closed immediately after each use, kept between 15 and 25 °C, and avoid contaminating the bottle with already used liquid.
At Hydroponics Blanes, this indoor cultivation accessory is part of the basic products to keep measuring equipment ready and readings more consistent throughout the entire cultivation cycle.
The pH 4.01 Calibration Solution 100 ml. AquaMaster is a reference buffer solution used to calibrate pH meters at an acidic point. This reference allows the meter to correctly recognize the pH 4.01 value and adjust the reading to provide more reliable measurements in daily cultivation work.
This product is used with AquaMaster meters and with other compatible meters that accept calibration with pH 4.01 standard solution. In crops where pH control directly influences nutrition, having a stable solution helps reduce errors and maintain a more precise measurement routine. The 100 ml container is practical for domestic, technical, or professional use, both in indoor cultivation and in propagation spaces, mother rooms, and fertilizer preparation areas.
The pH 4.01 Calibration Solution 100 ml. AquaMaster is used to calibrate any compatible pH meter and ensure that readings are reliable when working with acidic values. In cannabis cultivation, a poorly measured pH can cause nutrient lockouts, apparent deficiencies, over-fertilization, or absorption problems in the root zone.
Calibration with pH 4.01 is especially recommended when you want to fine-tune the accuracy of the meter after calibrating with pH 7.00. This two-point process allows the equipment to respond better within the usual working range of many nutrient solutions. It is also necessary to calibrate after replacing the electrode, after a long period without using the meter, or when readings start to show unusual variations.
For daily use, it is advisable to calibrate the meter every 2 or 3 weeks. For occasional use, monthly calibration can help keep the equipment in proper condition. This simple routine improves irrigation control and allows you to work with safer data before correcting the pH.
To use the pH 4.01 Calibration Solution 100 ml. AquaMaster, first turn on the pH meter and clean the electrode with distilled water or a specific electrode cleaning solution. Then, dry it with clean paper by gently dabbing, without rubbing hard to avoid damaging the sensitive part of the meter.
In a complete calibration, you usually start with pH 7.00 calibration solution and then continue with pH 4.01. Once the first phase is finished, clean the electrode again and insert it vertically into the pH 4.01 calibration solution. Shake very gently and wait for the measurement to stabilize. Then, activate the calibration mode following the manufacturer's instructions for the meter. In many AquaMaster models, the CAL button must be held down for several seconds until the screen value confirms the process.
To avoid contamination, it is advisable to pour a small amount of liquid into a clean container and discard it after each use. Used liquid should not be returned to the original bottle. This practice helps keep the solution in better condition and avoids deviations in future calibrations.
Buying pH 4.01 Calibration Solution 100 ml. AquaMaster is a highly recommended option for any grower who uses pH meters in the preparation of irrigation water. Although the meter may seem to work correctly, over time it can drift due to use, improper storage, fertilizer residues, or electrode aging. Periodic calibration allows you to regain more reliable readings and avoid errors in plant nutrition.
At Hydroponics Blanes, trusted Grow Shop, this product fits within the control and measurement section for cultivation. It is a basic complement along with pH 7.00 calibration solutions, cleaning solutions, storage solutions, and digital pH and EC meters.
The Price pH 4.01 Calibration Solution 100 ml. AquaMaster may vary depending on availability, active promotions, or purchase format. The individual 100 ml bottle is suitable for individual growers, while boxes of 18 bottles may be of interest to professionals, stores, grow rooms, or users who need to calibrate several devices regularly.
Consulting the product sheet allows you to see the updated price, available units, and shipping conditions. As it is a technical consumable, it is advisable to always have a bottle in the grow area to check the meter when necessary.
You can buy pH 4.01 Calibration Solution 100 ml. AquaMaster online at Hydroponics Blanes, a Grow Shop in Spain specializing in fertilizers, meters, control accessories, and products for indoor cultivation. The store offers discreet shipping and a catalog designed for growers who want to keep essential parameters such as pH, EC, temperature, and humidity under control.
The pH 4.01 Calibration Solution 100 ml. AquaMaster is a indoor cultivation accessory very useful for working with more stable measurements and avoiding pH adjustments based on incorrect readings. Having a reliable standard solution helps prepare irrigation with greater safety, take care of nutrient absorption, and maintain a more precise technical routine in each phase of cannabis cultivation.