Mixing reverse osmosis water and tap water is a way to adjust the mineral content of irrigation water in indoor growing. Understanding the mixing ratios, measuring EC, and checking calcium and magnesium levels helps create a more suitable water base before adding fertilizers.
When we use tap water, we do not always know exactly which minerals we are supplying to our plants. In some areas, water has high electrical conductivity, while in others it contains moderate amounts of calcium, magnesium, and bicarbonates. Reverse osmosis water allows us to reduce many of these elements, but it also removes minerals that can be beneficial for plant nutrition.
For this reason, in certain situations, combining both types of water can be an interesting alternative to using tap water or reverse osmosis water exclusively. However, there is no universal mixing ratio suitable for every growing system. The appropriate mixture depends on the composition of the available water, the growing method, and the fertilization program.
In this guide from the Hydroponics Blanes blog, we will explain how to calculate mixing ratios, what happens to EC, hardness, and alkalinity, and how to prepare irrigation water using numerical examples based on a real water analysis from Blanes.
Why Mix Reverse Osmosis Water and Tap Water for Indoor Growing?
The main purpose of mixing reverse osmosis water with tap water is to adjust the concentration of minerals present in the water before adding fertilizers.
Reverse osmosis water is produced using a membrane that removes a large proportion of dissolved salts. The result is water with a reduced mineral content, whose EC is usually considerably lower than that of the original water.
Tap water, on the other hand, may supply calcium, magnesium, and other elements, but it can also contain sodium, chlorides, and bicarbonates. Their concentrations depend on the local water supply network.
By combining both water sources, we can achieve several effects:
- Reduce the initial EC of tap water before adding fertilizers.
- Lower sodium and chloride concentrations when these elements are present at high levels.
- Take advantage of some of the calcium and magnesium naturally present in tap water.
- Reduce alkalinity when reverse osmosis water has very low alkalinity.
- Adjust mineral content according to the fertilizer and growing system.
This combination can be useful for soil, coco coir, and hydroponic growing systems, although each has different nutritional requirements.
If you are not yet familiar with the composition of your local water supply, we recommend reading our article Tap Water for Indoor Growing: How to Understand Hardness and Alkalinity Before Watering.

Differences Between EC, Hardness, and Alkalinity Before Mixing Water
Before calculating mixing ratios, we need to distinguish between three parameters that are often confused: electrical conductivity, hardness, and alkalinity.
Electrical Conductivity or EC
The EC of irrigation water indicates its ability to conduct electricity due to the presence of dissolved ions. It is usually expressed in mS/cm or µS/cm.
Generally, the higher the concentration of dissolved salts, the higher the electrical conductivity.
However, an EC reading does not identify which elements are present in the water. Two water samples may have similar EC readings but very different mineral compositions.
For example, part of the conductivity may come from calcium and magnesium, while another portion may be associated with sodium, chlorides, and other ions.
Water Hardness
Water hardness is mainly related to the concentration of calcium and magnesium. It is usually expressed as mg/L of calcium carbonate equivalent (CaCO3).
When we add reverse osmosis water with very low mineral content, the concentrations of these elements decrease. This can be useful when tap water is excessively hard, but it also means that its nutritional contribution is reduced.
Water Alkalinity
Alkalinity represents the ability of water to neutralize acids and is mainly associated with the presence of bicarbonates.
Water with high alkalinity may require a larger amount of acid-based pH adjuster to change its pH. In addition, continuous use may contribute to a gradual increase in pH in certain growing substrates.
It is important to remember that pH and alkalinity are not the same thing. Two water samples with similar pH values may react very differently when fertilizers or pH regulators are added.
How to Calculate Reverse Osmosis and Tap Water Mixing Ratios
To prepare a mixture, we need to know the total volume of water required and the percentage that will come from each source.
The formula is simple:
Liters of tap water = total liters × percentage of tap water / 100.
The remaining volume is filled with reverse osmosis water.
For example, if we want to prepare 10 liters of water using 30% tap water:
- 10 × 30 / 100 = 3 liters of tap water.
- 10 – 3 = 7 liters of reverse osmosis water.
The final mixture will contain 3 liters of tap water and 7 liters of reverse osmosis water.
Mixing Ratio Table for Preparing 10 Liters of Water
| Tap Water | Reverse Osmosis Water | Total Volume |
|---|---|---|
| 2.5 liters (25%) | 7.5 liters (75%) | 10 liters |
| 5 liters (50%) | 5 liters (50%) | 10 liters |
| 7.5 liters (75%) | 2.5 liters (25%) | 10 liters |
| 10 liters (100%) | 0 liters (0%) | 10 liters |
These ratios are calculation examples, not universal recommendations. To determine which one to use, it is necessary to understand the minerals present in the original water.
Real Example: Mixing Reverse Osmosis Water with Tap Water from Blanes
In our previous article, we analyzed data from a water quality report issued by Aigües de Blanes, corresponding to a sample collected on December 29, 2025.
The analysis reported the following results:
| Parameter | Tap Water from Blanes |
|---|---|
| Calcium | 42 mg/L |
| Magnesium | 8 mg/L |
| Total Hardness | 137 mg/L as CaCO3 |
| Total Alkalinity | 109.2 mg/L (reporting basis not specified) |
| EC at 20 °C | 0.562 mS/cm |
| Sodium | 68.5 mg/L |
| Chlorides | 115 mg/L |
These results describe one specific sample and should not be interpreted as permanent values for the entire water supply network.
For our example, we will use reverse osmosis water with a hypothetical EC of 0.020 mS/cm and virtually zero calcium and magnesium concentrations.
What Happens When We Mix the Two Types of Water?
When we mix water sources with known compositions, we can estimate the final concentration of each mineral using a volume-weighted average.
An approximate estimate can also be made for EC, although actual readings may differ due to ionic composition, temperature, and interactions between the components.
| Tap Water/RO Ratio | Estimated EC | Calcium | Magnesium |
|---|---|---|---|
| 100% / 0% | 0.562 mS/cm | 42 mg/L | 8 mg/L |
| 75% / 25% | 0.427 mS/cm | 31.5 mg/L | 6 mg/L |
| 50% / 50% | 0.291 mS/cm | 21 mg/L | 4 mg/L |
| 25% / 75% | 0.156 mS/cm | 10.5 mg/L | 2 mg/L |
| 0% / 100% | 0.020 mS/cm | Practically 0 | Practically 0 |
Important: these values are approximate, apply before adding fertilizers, and assume a negligible mineral contribution from reverse osmosis water. The final EC must be measured directly.
We can see that a 50% mixture reduces the calcium and magnesium contributions from tap water by approximately half. A mixture containing only 25% tap water reduces these minerals even further.
This demonstrates that achieving a low initial EC does not necessarily mean obtaining a balanced nutritional composition.
How to Calculate the Approximate EC of a Water Mixture
To make an initial estimate of electrical conductivity, we can use the following formula:
Estimated EC = [(tap water EC × liters of tap water) + (RO water EC × liters of RO water)] / total liters.
Let’s imagine we use:
- 6 liters of tap water with an EC of 0.60 mS/cm.
- 4 liters of reverse osmosis water with an EC of 0.02 mS/cm.
The calculation would be:
(0.60 × 6 + 0.02 × 4) / 10 = 0.368 mS/cm.
The expected reading would be approximately 0.37 mS/cm before adding fertilizers.
This calculation is an approximation, not a guarantee of the actual EC. To verify the result, we must use a properly calibrated conductivity meter and measure the mixture once it has been thoroughly mixed.
If you need to review how these instruments work, consult our guide EC in Indoor Growing: What It Is, How to Measure It, and Values by Growth Stage.
What Is the Best Ratio of Reverse Osmosis Water to Tap Water?
We cannot recommend a specific ratio based solely on EC. The mixture mainly depends on the quality of the available water, the needs of the crop, and the fertilizer we intend to use.
Mixtures Containing 25% Tap Water
These mixtures considerably reduce the original mineral content and may be useful when we need to lower the concentration of certain elements present in tap water.
However, they also significantly reduce the amount of calcium and magnesium available before fertilization.
Mixtures Containing 50% Tap Water and 50% Reverse Osmosis Water
A mixture of equal parts allows us to retain approximately half of the initial concentration of many minerals, provided their presence in reverse osmosis water is negligible.
It can be used as a starting point for testing, but it does not guarantee that the final solution contains sufficient calcium or magnesium.
Mixtures Containing 75% Tap Water
With this ratio, we retain a significant portion of the original mineral content while moderately reducing dissolved salt concentrations.
This may be an alternative when tap water has a reasonably suitable composition and we only want to partially reduce certain parameters.
The ideal ratio should be selected based on a water analysis and the nutritional program, not simply on an EC reading.
How Alkalinity Changes When Reverse Osmosis Water Is Added
One of the most interesting effects of mixing both types of water is the possibility of reducing the original alkalinity.
If tap water contains a significant concentration of bicarbonates and reverse osmosis water has almost no alkalinity, the mixture reduces the amount of alkalinity per liter approximately in proportion to the volumes used.
For example, if a water analysis reports an alkalinity of 120 mg/L as CaCO3, a 50% mixture with water containing virtually no alkalinity would have approximately 60 mg/L as CaCO3.
It is essential that both results are expressed in the same units.
Reducing alkalinity can make pH adjustment easier and decrease the alkalizing effect of repeated watering on certain growing substrates.
However, we should not calculate the pH of the mixture by taking an arithmetic average of the original pH values. The pH scale is logarithmic, and the final result depends on chemical equilibria and the buffering capacity of each water source.
The correct way to determine the final pH is to measure it directly.
When to Add Calcium and Magnesium to Reverse Osmosis Water
One of the most common questions is whether it is necessary to add a CalMag supplement after mixing reverse osmosis water with tap water.
The answer depends on three factors:
- The amount of calcium and magnesium supplied by the original water.
- The proportion of tap water used.
- The composition and dosage of the base fertilizer.
For example, if a mixture contains 21 mg/L of calcium and 4 mg/L of magnesium before fertilization, we need to check how much of these minerals will subsequently be supplied by the fertilizer.
Some nutrient programs are specifically formulated for soft water and contain higher amounts of these elements. Others are designed for water with greater mineral content.
Therefore, automatically adding CalMag can lead to excess nutrients or alter the proportions between calcium, magnesium, and other elements.
At Hydroponics Blanes, we offer supplements such as CalMag 1 Kg Green House and CalMag 1 Liter Hesi, designed to supplement mineral levels when genuinely necessary.
Before choosing a product, we recommend reading our article Calcium and Magnesium in Indoor Growing: When to Use CalMag.
How to Properly Prepare a Water Mixture for Irrigation
Once we have determined the ratio we want to use, we should prepare the solution by following an organized procedure.
1. Measure the EC of Both Water Sources
Before mixing them, we measure the EC of the tap water and the water produced by the reverse osmosis system.
This check also helps detect possible changes in the water supply or a decline in the performance of the reverse osmosis membrane.
2. Calculate the Required Volume
We determine the total volume and calculate the amount of each water source using the selected ratios.
It is advisable to work with a clean container and use reliable volume measurements.
3. Mix the Water and Check Conductivity
We add both water sources to the reservoir and stir until the mixture is homogeneous.
We then measure the initial EC and record the result.
If the reading is significantly different from the expected value, it is advisable to check the original measurements, the mixing ratios, and the condition of the conductivity meter.
4. Check Calcium and Magnesium Contributions
We consult the tap water analysis and calculate the approximate concentration of both minerals after dilution.
We then review the composition of the base fertilizer to determine whether any adjustments are necessary.
5. Add the Fertilizers
We add the products following the order and dosages recommended by their manufacturers, thoroughly mixing each component before adding the next one.
Incompatible concentrated fertilizers should never be mixed directly with each other.
6. Measure EC and Adjust the Final pH
Once the nutrient solution has been prepared, we check its EC and measure its pH.
If adjustment is required, we use a suitable pH regulator while following the manufacturer’s safety instructions.
After each correction, we should mix the solution and measure again to verify the result.
For more information about this procedure, we recommend reading How to Measure Irrigation Water pH and Adjust It Correctly.
Is It Better to Mix Reverse Osmosis Water or Use It at 100%?
Both options can be suitable depending on the growing system and fertilization program.
Using only reverse osmosis water allows us to start with very low mineral content and control more precisely which elements are introduced through fertilizers.
However, it also requires attention to the supply of calcium, magnesium, and other essential nutrients.
On the other hand, combining reverse osmosis water with tap water allows us to take advantage of some of the original mineral content, although a portion of the salts present in tap water will also remain.
When the water supply contains problematic concentrations of sodium, chlorides, or other elements, partial mixing may not be sufficient to achieve suitable water quality.
For this reason, the decision should be based on the composition of the water rather than simply trying to achieve a particular EC reading.
Common Mistakes When Mixing Reverse Osmosis and Tap Water
When preparing irrigation water, we may make mistakes that make plant nutrition more difficult to manage.
- Choosing a fixed ratio without analyzing the water: a mixture that works in one location may not be suitable in another.
- Confusing EC with calcium concentration: conductivity may also come from sodium, chlorides, and other ions.
- Calculating pH using an average: the final pH must be measured because it does not behave like a mineral concentration.
- Automatically adding CalMag: we should first review the mineral contributions from the water and base fertilizer.
- Failing to measure after mixing: mathematical estimates should be checked using suitable instruments.
- Ignoring alkalinity: water with moderate EC may contain enough bicarbonates to influence substrate pH.
- Using uncalibrated meters: an incorrect reading may lead us to modify a solution that was already properly prepared.
- Failing to check the reverse osmosis system: a deteriorated membrane may produce water with a higher mineral concentration than usual.
Recommended Meters and Equipment for Monitoring Irrigation Water
To prepare consistent and reproducible mixtures, it is important to use reliable instruments and keep them properly calibrated.
At Hydroponics Blanes, you will find a selection of pH and EC meters designed for monitoring irrigation water and nutrient solutions.
A conductivity meter allows us to check the initial mineral content of each water source and measure the result after mixing. A pH meter, meanwhile, allows us to verify the final conditions of the solution before watering.
We also offer water treatment equipment and reverse osmosis systems for producing water with reduced mineral content.
Among these products is the Growmax Mega Grow 1000 L/day Reverse Osmosis System, designed to produce treated water through reverse osmosis.
Choosing the right system will depend on daily water consumption, available water pressure, incoming water quality, and maintenance requirements.
Frequently Asked Questions About Mixing Reverse Osmosis and Tap Water
Can I Mix Reverse Osmosis Water and Tap Water Directly?
Yes. Both types of water can be mixed in a clean container. The important thing is to know their composition, use measured proportions, and check the resulting parameters before preparing the nutrient solution.
Does a 50% Mixture Reduce EC by Exactly Half?
Not necessarily. Reverse osmosis water may have an EC greater than zero, and the conductivity of the mixture does not always follow a perfectly linear relationship. The estimate serves as a reference, but it should be verified through measurement.
Do I Need to Add CalMag When Using Reverse Osmosis Water?
Not always. It depends on the amount of calcium and magnesium supplied by the fertilizers and the nutritional requirements of the crop.
Does Mixing Reverse Osmosis Water Reduce Bicarbonates?
Generally, yes, when tap water is combined with reverse osmosis water that has very low alkalinity. The reduction depends on the mixing ratio and the alkalinity of both water sources.
What EC Should Water Have Before Adding Fertilizers?
There is no universal value. The initial EC should be interpreted together with the mineral composition of the water, the fertilization program, and the needs of the crop. A low EC does not guarantee that the water has a suitable nutritional composition.
Conclusion: How to Achieve Better-Balanced Irrigation Water
Mixing reverse osmosis water and tap water allows us to modify the initial mineral content of the water and adapt its composition to certain requirements of indoor growing.
However, achieving good results involves more than simply reducing electrical conductivity. We must also consider calcium and magnesium contributions, the presence of sodium and chlorides, alkalinity, and the composition of the fertilizers being used.
The best strategy is to understand the starting water quality, calculate an approximate mixing ratio, verify the actual parameters, and keep a record of each preparation.
At Hydroponics Blanes, your trusted Grow Shop, you will find measuring instruments, reverse osmosis systems, fertilizers, and accessories for preparing and monitoring irrigation water. You can explore our catalog at www.growshopweb.com, with discreet shipping and specialized advice.
This article is provided for informational purposes only and focuses on understanding water quality and plant nutrition. Hydroponics Blanes sells cultivation equipment and supplies, but does not sell marijuana containing THC.